Skip to product information
1 of 9

FMFPAX

Dental Orthodontic Spot Welder HL-WD III, for Stainless Steel Wire and Arch Wire | FMFPAX

Regular price $453.57 USD
Regular price Sale price $453.57 USD
Price includes duties & taxes. Shipping calculated at checkout.
Voltage
Quantity
  • 1-year warranty on machinery core parts. Free replacement parts shipped to you — no need to return the machine.
  • Duties and import taxes included for delivery to United States (DDP). No extra customs charges on arrival. Details
  • Ships within 2 business days. Air express 7–15 days, land freight 20–30 days, sea freight 30–50 days after dispatch.
  • Questions before you buy? WhatsApp +86 158 1830 7991 or sales@fmfpack.com

Secure checkout with PayPal, major credit cards or bank transfer. PayPal Buyer Protection

Accepted secure payment methods

Mastercard Visa American Express PayPal Discover JCB Bank Transfer

HL-WD III Dental Orthodontic Spot Welder

The HL-WD III is a multi-function dental orthodontic spot welder for welding stainless steel wire and stainless steel sheet. It also supports brazing and heat treatment for orthodontic arch wire forming.

User Manual: Read the HL-WD III user manual online or download the PDF (covers HL-WD / II / III).

Functions

  • Spot welding mode for stainless steel wire and stainless steel sheet.
  • Brazing mode for supported dental orthodontic welding work.
  • Heat treatment mode for arch wire forming work.
  • LCD display with power and mode adjustment buttons.
  • Start button and foot switch operation for welding control.
  • Improper-operation error alarm and transformer overheating protection.

Technical Parameters

Model HL-WD III
Power supply options 110 V / 60 Hz or 220 V / 50 Hz variants
Maximum instantaneous current 20 A
Transformer output power 2000 W
Output voltage 5 V
Spot welding energy adjustment dXX, 1-30
Brazing energy adjustment q_X, 1-9
Heat treatment energy adjustment h_X, 1-9
Weldment range 0.2-1.8 mm stainless steel wire
Fuse 5 x 20 mm, 20 A
Overheating protection 85°C
Operating environment 5°C-40°C, relative humidity <=80%
Storage environment -10°C-55°C, relative humidity <=80%
Safety type Class I, Type B

Packing List

  • Main machine
  • Power cord
  • Foot switch
  • 20 A fuse (1)
  • Function clamps (2)
  • State block
  • Heat treatment clamp holder
  • Certificate
  • Warranty card
  • Manual

Safety

  • Use only by trained persons.
  • Wear insulating gloves during operation.
  • The electrodes and the heat treatment poles output energy at the same time. Do not touch the heat treatment poles while welding.
  • In heat treatment, place the state block between the electrode arms.
  • Do not let the heads of the two function clamps touch.

Power Setting by Wire Diameter

Power setting that gave a good weld in the manual’s test report (stainless steel, parallel welding)
Wire diameter 210 V 220 V 230 V Stabilized supply
0.2 mm 3 2 1 3
0.3 mm 5 4 3 5
0.4 mm 7 6 5 7
0.5 mm 9 8 7 9
0.6 mm 11 10 9 11
0.7 mm 13 12 11 13
0.8 mm 15 14 13 15
0.9 mm 17 16 15 17
1.0 mm 19 18 17 19
1.2 mm 21 20 19 21
1.4 mm 24 22 21 24
1.6 mm 27 25 24 27
1.8 mm 30 28 27 30

FAQ

What is the HL-WD III dental spot welder used for?

It is used for dental orthodontic welding work on stainless steel wire and stainless steel sheet, and for heat treatment of arch wire materials used in orthodontic forming work.

Which working modes does this machine support?

The HL-WD III supports spot welding, brazing, and heat treatment modes. The display shows dXX for spot welding, q_X for brazing, and h_X for heat treatment.

What stainless steel wire diameter range is listed in the manual?

The manual lists a weldment range of 0.2-1.8 mm stainless steel wire.

Can I choose the voltage?

This listing includes 110 V and 220 V variant options. Please select the required voltage before ordering.

Where can I read the full operation instructions?

Read the HL-WD III user manual online or download the PDF from the manual link above.

What power setting should I use for 1.0 mm wire?

The manual's test report records setting 19 at 210 V, 18 at 220 V, 17 at 230 V and 19 with a stabilized supply for 1.0 mm stainless steel. See the table above for 0.2-1.8 mm.

Why does the display show Err and the buzzer beep?

The mode on the display does not match the electrode setup. Spot welding (dXX) and braze welding (q_X) need the state block removed from between the electrode arms. Heat treatment (h_X) needs the state block placed between the arms.

View full details