FMF
CENTER 301 デュアル入力 Kタイプ熱電対温度計
受取状況を読み込めませんでした
CENTER 301 Dual Input K-Type Thermocouple Thermometer
The CENTER 301 is a dual input digital thermometer for Type K thermocouple temperature measurement. It supports T1 and T2 probe inputs so users can compare two temperature points on the same handheld meter.
This contact temperature meter is listed with a K-type measuring range of -200 to 1370 °C (-328 to 2498 °F), 0.1 °C / 0.1 °F resolution, and ±0.3% + 1 °C accuracy.
Suitable Uses
- Dual-channel Type K thermocouple temperature checking.
- Comparing two probe readings with T1 and T2 inputs.
- Field temperature measurement where a handheld contact thermometer is required.
- Testing and maintenance work that needs °C/°F switching and HOLD or MAX/MIN readings.
Key Features
- Dual input and dual display layout for two Type K thermocouple probes.
- T1, T2, and T1-T2 buttons visible on the meter for comparison readings.
- 0.1 °C / 0.1 °F resolution for fine temperature reading.
- HOLD, REL, AVG, MAX, and MIN function buttons shown on the meter.
- Auto power off function listed for saving the 9V battery during field work.
- Product images show the CENTER 301 meter, two Type K probe leads, packaging, manuals, and a soft carry case.
Specifications
| Model | CENTER 301 |
| Product type | Dual input Type K thermocouple thermometer |
| Input | T1 and T2 Type K thermocouple inputs |
| K-type range | -200 to 1370 °C / -328 to 2498 °F |
| Resolution | 0.1 °C / 0.1 °F |
| Accuracy | ±0.3% + 1 °C / ±0.3% + 1.8 °F |
| Operating temperature | 0 to 50 °C, <80% RH |
| Storage temperature | -20 to 60 °C, <70% RH |
| Power | 9V battery |
| Dimensions | 184 x 64 x 30 mm |
| Meter weight | Approx. 210 g |
| Option | CENTER301 |
| SKU reference | FMF-TM-84537-CENTER301 |
How It Works
- Install a 9V battery before use.
- Connect one or two Type K thermocouple probes to the T1 and T2 inputs.
- Select °C or °F as needed.
- Use T1, T2, or T1-T2 mode to read one channel or compare two probe readings.
- Use HOLD or MAX/MIN functions when a stable or peak reading needs to be checked.
Selection Notes
- Select this model when you need contact Type K thermocouple probe readings.
- Confirm that your probe type is Type K and that the temperature range fits your application.
- For functions not listed on this page, confirm the required model before ordering.
FAQ
What is the CENTER 301 used for?
It is used for contact temperature measurement with Type K thermocouple probes, including two-point T1/T2 readings.
Does it support two probes at the same time?
Yes. The product information and images show T1 and T2 inputs for dual-channel readings.
What temperature range is listed?
The listed K-type range is -200 to 1370 °C, or -328 to 2498 °F.
Can it switch between Celsius and Fahrenheit?
Yes. The product information lists 0.1 °C / 0.1 °F resolution, and the meter shows a °C/°F button.
What should I confirm before ordering?
Confirm the probe type, temperature range, battery requirement, and any function that is not listed on this page.