Characteristics
The AC/DC withstand voltage test function adopts DDS digital signal synthesis technology, generating accurate, stable, pure, and low-distortion waveforms.
The high-voltage rise and fall time is adjustable to meet the testing requirements of different test objects. It also features arc detection, and test results can be stored simultaneously.
Supports dual-frequency comprehensive testing with selectable 50Hz and 60Hz frequencies. The user-friendly interface supports digital keypad input and rotary knob input for easier operation.
Provides complete operation help prompts, effectively improving user efficiency. Supports character-based file name input, with a maximum file name length of 12 characters.
Test steps and system status information are displayed synchronously, allowing users to clearly monitor the testing process and system status in real time.
Features a bilingual operation interface to meet the needs of different users and supports large-capacity data storage, adapting to various testing application requirements.
Model |
AC-DC insulation withstand voltage tester |
AC DC insulation withstand voltage tester |
AC DC voltage tester |
AC voltage tester |
|
RK9310 |
RK9320 |
RK9320A |
RK9320B |
||
Ac withstand voltage test |
Voltage range |
0.050kV ~ 5.000kV |
|||
Voltage accuracy |
±(2%+5V) |
||||
Resolution |
1V |
||||
Maximum output power |
50VA ( 5.000kV/10mA) |
100VA ( 5.000kV/20mA) |
|||
Maximum rated current |
0~10mA |
0~20mA |
|||
Lower current range |
0 ~10mA,0=Lower limit of nonjudgment |
0 ~ 20mA,OFF=Lower limit of nonjudgment |
|||
Output waveform |
Sinusoidal wave |
||||
Output waveform distortion degree |
≤ 5% (no-load or pure resistive load) |
||||
Output signal type |
DDS linear power amplifier |
||||
Voltage rise time |
0.1s~999.9s,OFF= voltage rise time off |
||||
Test time |
0.1s~999.9s,OFF= continuous test |
||||
Voltage drop time |
0.1s~999.9s,OFF= voltage drop time off |
||||
|
DC withstand voltage test |
Voltage range |
0.050kV ~ 6.000kV |
/ |
||
Voltage accuracy |
±(2%+5V) |
||||
Resolution |
1V |
||||
|
Maximum output power |
30W ( 6.000kV/5mA) |
60W ( 6.000kV/10mA) |
|||
|
Maximum rated current |
0 ~ 5mA |
0 ~ 10mA |
|||
|
Lower limit current range |
0 ~ 5mA |
0 ~ 10mA |
|||
|
Ripple factor |
≤ 5% (6kV/5mA) |
≤ 5% (6kV/10mA) |
|||
|
Discharge time |
≤ 200ms |
||||
|
voltage rise time |
0.1s ~ 999.9s ,OFF= Voltage rise time off |
||||
|
Test time |
0.3s ~ 999.9s ,OFF= Continuous testing |
||||
|
Voltage drop time |
0.1s ~ 999.9s ,OFF= Voltage drop time off |
||||
|
Insulation test |
Output voltage setting |
0.050kV ~ 5. 000kV Resolution: 1V volts/Step |
/ |
||
|
Resistance upper limit setting |
Range: (0.2M ~ 100) GΩ |
||||
|
Lower limit setting of resistance |
Range: (0.1M ~ 100) GΩ |
||||
|
voltage rise time |
0.1s ~ 999.9s ,OFF= Voltage rise time off |
||||
|
Test time |
0.3s ~ 999.9s ,OFF= Continuous testing |
||||
|
Voltage drop time |
0.1s ~ 999.9s ,OFF= Voltage drop time off |
||||
|
ohmmeter |
≥500v 0.10MΩ-1.0GΩ ±5% 1.0G-50.0 GΩ ±10% |
||||
Arc detection |
1mA-10mA |
1mA-20mA |
|||
Input characteristic |
100V~240V 50Hz/60Hz |
||||
Screen size |
3.5-inch TFT LCD screen |
||||
Communication interface |
HANDLER, RS232, USB interface, LAN |
||||
External (W × D × H) |
400*260*88mm |
||||
Weight (KG) |
6.5KG |
||||

RK9310/20 Series Instrument
Product Calibration Certificate
Product Qualification Certificate
RS232 to USB Connection Cable (Optional)
RS232 Serial Port Cable
Power Cord
Cross-type Uncontrolled High-Voltage Rod (Optional)
High-Voltage Test Clip
Test Lead
Dual-End BNC Cable (Standard for RK9320AY)
High-Voltage Test Gun (Standard for RK9320AY)