{"product_id":"bst600-ac-dc-gaussmeter-teslameter-horizontal-hall-probe","title":"BST600 AC\/DC Gaussmeter Teslameter with Horizontal Hall Probe, 0-2000 mT","description":"\u003csection\u003e\n  \u003ch2\u003eBST600 AC\/DC Gaussmeter with Horizontal Hall Probe\u003c\/h2\u003e\n  \u003cp\u003eThe BST600 is a portable gaussmeter\/teslameter for measuring magnetic flux density in DC and AC magnetic fields. This version is supplied with a horizontal Hall probe for surface magnetic field checks, with selectable 0-200 mT and 0-2000 mT ranges, mT\/Gs unit conversion, zero reset, and peak hold.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eWhat It Measures\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eMagnetic flux density on magnet and material surfaces.\u003c\/li\u003e\n    \u003cli\u003eWorking magnetic fields from magnetic separators, iron-removing equipment, magnetic chucks, magnet coils, and demagnetizing coils.\u003c\/li\u003e\n    \u003cli\u003eLeakage magnetic fields on iron surfaces.\u003c\/li\u003e\n    \u003cli\u003eMagnetic fields inside gaps and narrow structures.\u003c\/li\u003e\n    \u003cli\u003eMagnetic field checks for DC motors, speakers, permanent magnetic separators, and induction cooker work areas.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eKey Functions\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eHall-effect sensor measurement with a microcontroller-controlled digital circuit.\u003c\/li\u003e\n    \u003cli\u003eMeasures both DC and AC magnetic fields.\u003c\/li\u003e\n    \u003cli\u003eTwo selectable ranges: 0-200 mT and 0-2000 mT.\u003c\/li\u003e\n    \u003cli\u003eSwitchable display units: mT and Gs. Reference conversion: 0.1 mT = 1 Gs; 1 T = 10,000 Gs.\u003c\/li\u003e\n    \u003cli\u003eZero reset for measurement setup away from magnetic fields.\u003c\/li\u003e\n    \u003cli\u003eReal-time measurement and peak-value hold modes.\u003c\/li\u003e\n    \u003cli\u003e9V battery operation for about 20 hours of continuous use.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eBST600 digital gaussmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor version\u003c\/th\u003e\n\u003ctd\u003eHorizontal Hall probe\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003e0-200 mT \/ 0-2000 mT\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±2%, ±3 digits; ±5%, ±5 digits at 1000 mT\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.01 mT \/ 0.1 mT\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasured field type\u003c\/th\u003e\n\u003ctd\u003eDC and AC magnetic fields\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003eDC-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e4.5-digit LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e9V battery or 9V DC external regulated power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e5°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20%-80%, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument dimensions\u003c\/th\u003e\n\u003ctd\u003e150 mm (L) x 70 mm (W) x 25 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eN.W. 400 g; G.W. 900 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003ePackage Contents\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eBST600 digital gaussmeter: 1 pc\u003c\/li\u003e\n    \u003cli\u003eHorizontal Hall probe: 1 pc\u003c\/li\u003e\n    \u003cli\u003eInstruction manual: 1 pc\u003c\/li\u003e\n    \u003cli\u003eCertificate document: 1 pc\u003c\/li\u003e\n    \u003cli\u003e9V battery: 1 pc\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eWhen to Choose This Model\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eChoose this horizontal sensor version when you need to check surface magnetic fields with the side\/contact surface of the probe.\u003c\/li\u003e\n    \u003cli\u003eUse the 0-200 mT range for lower field readings and the 0-2000 mT range for stronger fields within the instrument range.\u003c\/li\u003e\n    \u003cli\u003eUse peak hold when you need to capture the highest reading during a measurement pass.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eBasic Operation\u003c\/h2\u003e\n  \u003col\u003e\n    \u003cli\u003eInstall the 9V battery, or connect a 9V DC regulated external power supply if used.\u003c\/li\u003e\n    \u003cli\u003eInsert the Hall probe into the front-panel sensor socket according to the arrow mark.\u003c\/li\u003e\n    \u003cli\u003ePower on the meter and keep the probe away from magnetic fields before zero adjustment.\u003c\/li\u003e\n    \u003cli\u003eSelect DC or AC mode, choose the 200 mT or 2000 mT range, and switch between mT and Gs as needed.\u003c\/li\u003e\n    \u003cli\u003eLightly contact the measurement surface with the proper sensing side of the horizontal probe. Do not press the probe tip hard against the workpiece.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFAQ\u003c\/h2\u003e\n  \u003ch3\u003eCan the BST600 measure both AC and DC magnetic fields?\u003c\/h3\u003e\n  \u003cp\u003eYes. The BST600 supports DC and AC magnetic field measurement, with a frequency range listed as DC-200 Hz.\u003c\/p\u003e\n  \u003ch3\u003eWhich probe version is supplied with this product?\u003c\/h3\u003e\n  \u003cp\u003eThis listing is for the horizontal Hall probe version.\u003c\/p\u003e\n  \u003ch3\u003eWhat units can the display show?\u003c\/h3\u003e\n  \u003cp\u003eThe display can be switched between mT and Gs.\u003c\/p\u003e\n  \u003ch3\u003eWhen should zero reset be used?\u003c\/h3\u003e\n  \u003cp\u003eReset zero with the probe away from magnetic fields before measurement, and reset again after changing the range or switching AC\/DC mode.\u003c\/p\u003e\n  \u003ch3\u003eWhat power supply does it use?\u003c\/h3\u003e\n  \u003cp\u003eThe meter uses a 9V battery and can also use a 9V DC external regulated power supply.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eProbe Care Notes\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eThe magnetic sensing element is at the front end of the Hall probe.\u003c\/li\u003e\n    \u003cli\u003eDo not bend, pull, strike, squeeze, or heavily load the probe and cable.\u003c\/li\u003e\n    \u003cli\u003eAvoid strong sunlight, high temperature, high humidity, water, oil, corrosive air, heavy vibration, and strong nearby magnetic fields during storage or use.\u003c\/li\u003e\n    \u003cli\u003eRemove the battery when the meter will not be used for a long time.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e","brand":"FMF Supply","offers":[{"title":"Horizontal Sensor","offer_id":43370939154521,"sku":"FMF-BST600-12217","price":281.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/12.jpg?v=1780663645","url":"https:\/\/fmfpack.com\/products\/bst600-ac-dc-gaussmeter-teslameter-horizontal-hall-probe","provider":"FMF Supply","version":"1.0","type":"link"}