{"product_id":"center-301-dual-input-digital-thermometer-200-1370-c-k-type-probe-0-1-c-0-1-f-resolution-0-3-accuracy","title":"CENTER 301 デュアル入力 Kタイプ熱電対温度計","description":"\u003csection\u003e\n  \u003ch2\u003eCENTER 301 Dual Input K-Type Thermocouple Thermometer\u003c\/h2\u003e\n  \u003cp\u003eThe CENTER 301 is a dual input digital thermometer for Type K thermocouple temperature measurement. It supports T1 and T2 probe inputs so users can compare two temperature points on the same handheld meter.\u003c\/p\u003e\n  \u003cp\u003eThis contact temperature meter is listed with a K-type measuring range of -200 to 1370 °C (-328 to 2498 °F), 0.1 °C \/ 0.1 °F resolution, and ±0.3% + 1 °C accuracy.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eSuitable Uses\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDual-channel Type K thermocouple temperature checking.\u003c\/li\u003e\n    \u003cli\u003eComparing two probe readings with T1 and T2 inputs.\u003c\/li\u003e\n    \u003cli\u003eField temperature measurement where a handheld contact thermometer is required.\u003c\/li\u003e\n    \u003cli\u003eTesting and maintenance work that needs °C\/°F switching and HOLD or MAX\/MIN readings.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDual input and dual display layout for two Type K thermocouple probes.\u003c\/li\u003e\n    \u003cli\u003eT1, T2, and T1-T2 buttons visible on the meter for comparison readings.\u003c\/li\u003e\n    \u003cli\u003e0.1 °C \/ 0.1 °F resolution for fine temperature reading.\u003c\/li\u003e\n    \u003cli\u003eHOLD, REL, AVG, MAX, and MIN function buttons shown on the meter.\u003c\/li\u003e\n    \u003cli\u003eAuto power off function listed for saving the 9V battery during field work.\u003c\/li\u003e\n    \u003cli\u003eProduct images show the CENTER 301 meter, two Type K probe leads, packaging, manuals, and a soft carry case.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eCENTER 301\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eProduct type\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eDual input Type K thermocouple thermometer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eInput\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eT1 and T2 Type K thermocouple inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eK-type range\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e-200 to 1370 °C \/ -328 to 2498 °F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e0.1 °C \/ 0.1 °F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eAccuracy\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e±0.3% + 1 °C \/ ±0.3% + 1.8 °F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eOperating temperature\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e0 to 50 °C, \u0026lt;80% RH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eStorage temperature\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e-20 to 60 °C, \u0026lt;70% RH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003ePower\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e9V battery\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eDimensions\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003e184 x 64 x 30 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eMeter weight\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eApprox. 210 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eOption\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eCENTER301\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eSKU reference\u003c\/td\u003e\n        \u003ctd style=\"border:1px solid #d9d9d9;padding:8px;\"\u003eFMF-TM-84537-CENTER301\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eHow It Works\u003c\/h3\u003e\n  \u003col\u003e\n    \u003cli\u003eInstall a 9V battery before use.\u003c\/li\u003e\n    \u003cli\u003eConnect one or two Type K thermocouple probes to the T1 and T2 inputs.\u003c\/li\u003e\n    \u003cli\u003eSelect °C or °F as needed.\u003c\/li\u003e\n    \u003cli\u003eUse T1, T2, or T1-T2 mode to read one channel or compare two probe readings.\u003c\/li\u003e\n    \u003cli\u003eUse HOLD or MAX\/MIN functions when a stable or peak reading needs to be checked.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eSelection Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eSelect this model when you need contact Type K thermocouple probe readings.\u003c\/li\u003e\n    \u003cli\u003eConfirm that your probe type is Type K and that the temperature range fits your application.\u003c\/li\u003e\n    \u003cli\u003eFor functions not listed on this page, confirm the required model before ordering.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eFAQ\u003c\/h3\u003e\n  \u003ch4\u003eWhat is the CENTER 301 used for?\u003c\/h4\u003e\n  \u003cp\u003eIt is used for contact temperature measurement with Type K thermocouple probes, including two-point T1\/T2 readings.\u003c\/p\u003e\n  \u003ch4\u003eDoes it support two probes at the same time?\u003c\/h4\u003e\n  \u003cp\u003eYes. The product information and images show T1 and T2 inputs for dual-channel readings.\u003c\/p\u003e\n  \u003ch4\u003eWhat temperature range is listed?\u003c\/h4\u003e\n  \u003cp\u003eThe listed K-type range is -200 to 1370 °C, or -328 to 2498 °F.\u003c\/p\u003e\n  \u003ch4\u003eCan it switch between Celsius and Fahrenheit?\u003c\/h4\u003e\n  \u003cp\u003eYes. The product information lists 0.1 °C \/ 0.1 °F resolution, and the meter shows a °C\/°F button.\u003c\/p\u003e\n  \u003ch4\u003eWhat should I confirm before ordering?\u003c\/h4\u003e\n  \u003cp\u003eConfirm the probe type, temperature range, battery requirement, and any function that is not listed on this page.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"FMF","offers":[{"title":"CENTER301","offer_id":43370938728537,"sku":"FMF-TM-84537-CENTER301","price":50.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/IMG_20170526_195124.jpg?v=1780655437","url":"https:\/\/fmfpack.com\/ja\/products\/center-301-%e3%83%87%e3%83%a5%e3%82%a2%e3%83%ab%e5%85%a5%e5%8a%9b%e3%83%87%e3%82%b8%e3%82%bf%e3%83%ab%e6%b8%a9%e5%ba%a6%e8%a8%88-200-1370-c-k%e3%82%bf%e3%82%a4%e3%83%97%e3%83%97%e3%83%ad%e3%83%bc%e3%83%96-0-1-c-0-1-f%e5%88%86%e8%a7%a3%e8%83%bd-0-3%e7%b2%be%e5%ba%a6","provider":"FMF Supply","version":"1.0","type":"link"}