{"title":"Attrezzature da laboratorio","description":"\u003cp\u003eStrumenti da laboratorio e miscelatori conservati come una collezione SEO ricercabile per acquirenti che necessitano di attrezzature da laboratorio al di fuori della navigazione principale degli imballaggi.\u003c\/p\u003e","products":[{"product_id":"2-pack-2kw-400mm-220v-uv-lamp-tubes-curing-machine","title":"2-Pack 2KW 400 mm 220V UV Curing Lamp Tubes","description":"\u003csection\u003e\n\u003ch2\u003e2-Pack UV Curing Lamp Tube Set\u003c\/h2\u003e\n\u003cp\u003eThis product is a 2-piece set of 2KW 400 mm 220V UV curing lamp tubes for UV curing machine replacement. One order quantity includes two replacement UV lamp tubes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSales unit\u003c\/th\u003e\n\u003ctd\u003e2 pcs\/lot, two lamp tubes per set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eUV lamp tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower rating\u003c\/th\u003e\n\u003ctd\u003e2KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp length\u003c\/th\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eReplacement lamp tube for UV curing machines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU reference\u003c\/th\u003e\n\u003ctd\u003eFMF-TM-03737\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2\u003eWhen to Choose This UV Lamp Tube\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eChoose this set when your UV curing equipment requires a 400 mm, 2KW, 220V lamp tube.\u003c\/li\u003e\n\u003cli\u003eThe 2-pack format is useful when replacing a pair of lamp tubes or keeping one tube as a spare.\u003c\/li\u003e\n\u003cli\u003eMatch the lamp length, power rating, voltage, and tube shape with your existing lamp or machine documentation before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 UV curing lamp tubes\u003c\/li\u003e\n\u003cli\u003eThis listing is for replacement lamp tubes, not a complete UV curing machine.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that your machine uses a 400 mm lamp tube rated 2KW and 220V.\u003c\/li\u003e\n\u003cli\u003eCompare the product photos with the lamp tube currently installed in your equipment.\u003c\/li\u003e\n\u003cli\u003eFor related machines and accessories, see \u003ca href=\"\/it-it\/collections\/uv-curing-printing-equipment\"\u003eUV Curing \u0026amp; Printing Equipment\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eHow many lamp tubes are included?\u003c\/h3\u003e\n\u003cp\u003eEach order quantity includes two UV lamp tubes. This item is sold as a 2 pcs\/lot set.\u003c\/p\u003e\n\u003ch3\u003eIs this a single lamp tube or a two-pack?\u003c\/h3\u003e\n\u003cp\u003eIt is a two-pack. The sales unit is 2 pcs\/lot.\u003c\/p\u003e\n\u003ch3\u003eWhat specifications should I confirm before purchase?\u003c\/h3\u003e\n\u003cp\u003eConfirm the 400 mm length, 2KW power rating, 220V voltage, and tube shape against your existing UV curing machine.\u003c\/p\u003e\n\u003ch3\u003eCan this fit any UV curing machine?\u003c\/h3\u003e\n\u003cp\u003eUse it only when your machine requires the same lamp length, power rating, voltage, and tube configuration. Machine-specific compatibility should be checked against your existing lamp or equipment documentation.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43370939809881,"sku":"FMF-TM-03737","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/IMG_20250403_122900.jpg?v=1780709220"},{"product_id":"td4c-8x20ml-low-speed-laboratory-centrifuge-4000rpm","title":"TD4C 8x20ml Centrifuga da laboratorio a bassa velocità 4000rpm Separatore di provette da banco","description":"\u003csection\u003e\u003ch2\u003ePanoramica del prodotto\u003c\/h2\u003e\n\u003cp\u003eLa TD4C è una centrifuga da laboratorio a bassa velocità di tipo da banco, progettata per la separazione di provette. Le immagini e l'etichetta del prodotto la identificano come una centrifuga a bassa velocità TD4C con rotore da 8 x 20 ml, display a 4000 RPM, comandi timer e pulsante Speed\/RCF.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTD4C centrifuga da laboratorio a bassa velocità da banco per la separazione di provette.\u003c\/li\u003e\n\u003cli\u003eRotore da 8 x 20 ml con otto posizioni per provette visibili.\u003c\/li\u003e\n\u003cli\u003eIl pannello frontale mostra 4000 RPM, display del tempo, comandi Start, Stop, Setup e Speed\/RCF.\u003c\/li\u003e\n\u003cli\u003eL'etichetta del prodotto indica ingresso AC110V, potenza totale 60W e fusibile 10A.\u003c\/li\u003e\n\u003cli\u003eFormato da banco per laboratori che necessitano di una centrifuga compatta per provette.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModello\u003c\/th\u003e\n\u003ctd\u003eTD4C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTipo di prodotto\u003c\/th\u003e\n\u003ctd\u003eCentrifuga da banco a bassa velocità\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFormato rotore\u003c\/th\u003e\n\u003ctd\u003e8 x 20 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVelocità visualizzata\u003c\/th\u003e\n\u003ctd\u003e4000 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComandi\u003c\/th\u003e\n\u003ctd\u003eImpostazione RPM, controllo tempo, Speed\/RCF, Start, Stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTensione nominale indicata in etichetta\u003c\/th\u003e\n\u003ctd\u003eAC110V +\/- 10V, 50Hz +\/- 1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotenza totale strumento indicata in etichetta\u003c\/th\u003e\n\u003ctd\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValore fusibile indicato in etichetta\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eFMF-I-71513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eNote per la selezione\u003c\/h2\u003e\n\u003cp\u003ePrima dell'ordine, verificare le dimensioni delle provette, i requisiti di tensione, la compatibilità del rotore e lo spazio disponibile sul banco. Assicurarsi che la configurazione della centrifuga sia conforme alle norme applicabili e ai requisiti del flusso di lavoro del sito.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eQuale formato di provette è previsto per questa centrifuga TD4C?\u003c\/h3\u003e\n\u003cp\u003eIl formato del rotore indicato è 8 x 20 ml e il prodotto include otto posizioni per provette all'interno del rotore.\u003c\/p\u003e\n\u003ch3\u003eQuali informazioni sulla velocità sono visibili sulla macchina?\u003c\/h3\u003e\n\u003cp\u003eIl display del pannello di controllo mostra 4000 RPM e include un pulsante Speed\/RCF per la visualizzazione della velocità o della forza centrifuga relativa.\u003c\/p\u003e\n\u003ch3\u003eCosa bisogna verificare prima dell'ordine?\u003c\/h3\u003e\n\u003cp\u003eControllare le dimensioni delle provette, la compatibilità del rotore, la tensione e lo spazio disponibile sul banco in base al flusso di lavoro di laboratorio previsto.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43370942136409,"sku":"FMF-I-71513","price":344.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/S2a4711fb36524355979193a5f93e6e13s.webp?v=1780390750"},{"product_id":"2waj-abbe-refractometer-nd-brix-0-95-measurement","title":"2WAJ Rifrattometro Abbe Brix 0-95% nD Strumento Ottico da Laboratorio","description":"\u003csection\u003e\u003ch2\u003eDettagli del prodotto\u003c\/h2\u003e\n\u003cp\u003eIl rifrattometro Abbe 2WAJ è uno strumento ottico da laboratorio per la misura dell'indice di rifrazione nD e del Brix. È progettato per misure su banco, ideale per chi necessita di un rifrattometro ottico diretto anziché di un misuratore di zucchero digitale portatile.\u003c\/p\u003e\n\u003cp\u003eIl campo di misura Brix è 0-95%. Per soluzioni saccarifere in questo intervallo, il contesto di misura dell'indice di rifrazione è 1.333-1.531. Lo strumento può essere collegato a un dispositivo a temperatura costante per prove controllate da 0 a 70 °C.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2WAJ Rifrattometro Abbe per misura di indice di rifrazione e Brix.\u003c\/li\u003e\n\u003cli\u003eCampo Brix 0-95% per misure su soluzioni zuccherine.\u003c\/li\u003e\n\u003cli\u003eMisura nD per test ottici di laboratorio.\u003c\/li\u003e\n\u003cli\u003eCompatibile con dispositivo a temperatura costante per prove controllate da 0 a 70 °C.\u003c\/li\u003e\n\u003cli\u003eStrumento ottico da banco per chi confronta rifrattometri Abbe, misuratori Brix e misuratori di indice di rifrazione.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eSpecifiche tecniche\u003c\/h2\u003e\n\u003cp\u003eLe specifiche principali di questo rifrattometro Abbe sono: modello 2WAJ, misura dell'indice di rifrazione nD, campo Brix 0-95%, contesto di indice di rifrazione per saccarosio 1.333-1.531 e supporto per prove a temperatura controllata da 0 a 70 °C.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModello\u003c\/th\u003e\n\u003ctd\u003e2WAJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTipo di strumento\u003c\/th\u003e\n\u003ctd\u003eRifrattometro Abbe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMisura\u003c\/th\u003e\n\u003ctd\u003eIndice di rifrazione nD e Brix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCampo Brix\u003c\/th\u003e\n\u003ctd\u003e0-95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContesto indice di rifrazione saccarosio\u003c\/th\u003e\n\u003ctd\u003e1.333-1.531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCampo di controllo temperatura\u003c\/th\u003e\n\u003ctd\u003e0-70 °C con dispositivo a temperatura costante\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eFMF-TM-02585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eNote di selezione\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQuesto rifrattometro Abbe è adatto per controlli Brix su soluzioni zuccherine, misura dell'indice di rifrazione nD e lavori di confronto ottico in laboratorio.\u003c\/li\u003e\n\u003cli\u003eScegliere questo modello quando il lavoro richiede un rifrattometro Abbe per controlli ottici dell'indice di rifrazione e del Brix.\u003c\/li\u003e\n\u003cli\u003ePer campioni diversi dalle soluzioni zuccherine, contattarci con il tipo di campione e il requisito di misura prima dell'ordine.\u003c\/li\u003e\n\u003cli\u003ePulire la superficie di lavoro del prisma rifrangente prima e dopo l'uso, specialmente quando si cambiano i campioni.\u003c\/li\u003e\n\u003cli\u003eEvitare forti vibrazioni, urti e campioni corrosivi che potrebbero danneggiare il prisma o il corpo dello strumento.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCosa misura il rifrattometro Abbe 2WAJ?\u003c\/h3\u003e\n\u003cp\u003eMisura l'indice di rifrazione nD e il Brix. Il campo Brix è 0-95%.\u003c\/p\u003e\n\u003ch3\u003eQuali specifiche controllare prima dell'ordine?\u003c\/h3\u003e\n\u003cp\u003eControllare il modello 2WAJ, campo Brix 0-95%, necessità di misura dell'indice di rifrazione nD, requisito di controllo temperatura 0-70 °C e SKU FMF-TM-02585.\u003c\/p\u003e\n\u003ch3\u003ePer quali campioni è adatto questo rifrattometro Abbe?\u003c\/h3\u003e\n\u003cp\u003eÈ adatto per controlli Brix su soluzioni zuccherine e misura dell'indice di rifrazione nD in lavori ottici di laboratorio.\u003c\/p\u003e\n\u003ch3\u003ePuò essere utilizzato per misure a temperatura controllata?\u003c\/h3\u003e\n\u003cp\u003eSì. Può essere collegato a un dispositivo a temperatura costante per prove nell'intervallo 0-70 °C.\u003c\/p\u003e\n\u003ch3\u003eÈ uguale a un misuratore Brix digitale portatile?\u003c\/h3\u003e\n\u003cp\u003eNo. Questo è un rifrattometro Abbe da banco per misure ottiche di laboratorio.\u003c\/p\u003e\n\u003ch3\u003eCome va curato il prisma?\u003c\/h3\u003e\n\u003cp\u003eMantenere pulita la superficie di lavoro del prisma rifrangente prima e dopo la misura, ed evitare campioni corrosivi.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43370942267481,"sku":"FMF-TM-02585","price":260.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/2waj-abbe-refractometer-nd-brix-0-95-measurement-01-white-bg.webp?v=1780454603"},{"product_id":"0-rotor-adapter-set-ndj-snb-rotary-viscometers-low-viscosity","title":"0# Set adattatore rotore per viscosimetri rotazionali NDJ\/SNB, 20-25mL bassa viscosità","description":"\n\u003csection\u003e\n  \u003ch2\u003eDettagli prodotto\u003c\/h2\u003e\n  \u003cp\u003eQuesto set adattatore rotore 0# è un accessorio per bassa viscosità per viscosimetri rotazionali NDJ e SNB compatibili. Consente di misurare campioni liquidi a bassa viscosità quando la gamma di rotori standard non è adatta.\u003c\/p\u003e\n  \u003cp\u003eIl set è utilizzato con i modelli di viscosimetro rotazionale NDJ-5S, NDJ-8S, NDJ-9S, SNB-1 e SNB-2. Verificare la compatibilità del modello dello strumento e del collegamento del rotore prima dell'ordine.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eCaratteristiche principali\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eSet adattatore rotore 0# per misurazioni a bassa viscosità con viscosimetro rotazionale.\u003c\/li\u003e\n    \u003cli\u003eModelli compatibili: NDJ-5S, NDJ-8S, NDJ-9S, SNB-1 e SNB-2.\u003c\/li\u003e\n    \u003cli\u003eVolume campione: 20-25 mL di liquido.\u003c\/li\u003e\n    \u003cli\u003eIntervallo di viscosità: da 0.01 mPa.s a 15 mPa.s.\u003c\/li\u003e\n    \u003cli\u003eLa struttura del rotore cilindrico consente il calcolo della velocità di taglio durante l'analisi del campione.\u003c\/li\u003e\n    \u003cli\u003eRiferimento SKU: FMF-NDJ-5S-05369.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eSpecifiche\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eTipo di accessorio\u003c\/th\u003e\n\u003ctd\u003eSet adattatore rotore 0#\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eTipo di strumento\u003c\/th\u003e\n\u003ctd\u003eAccessorio per viscosimetro rotazionale\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eModelli compatibili\u003c\/th\u003e\n\u003ctd\u003eNDJ-5S, NDJ-8S, NDJ-9S, SNB-1, SNB-2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eVolume campione\u003c\/th\u003e\n\u003ctd\u003e20-25 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntervallo di viscosità\u003c\/th\u003e\n\u003ctd\u003eda 0.01 a 15 mPa.s\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eStruttura del rotore\u003c\/th\u003e\n\u003ctd\u003eRotore cilindrico\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eFMF-NDJ-5S-05369\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eNote di installazione\u003c\/h2\u003e\n  \u003col\u003e\n    \u003cli\u003eMontare il rotore 0# sulla vite di attacco in senso antiorario.\u003c\/li\u003e\n    \u003cli\u003eVersare 20-25 mL di campione liquido nella provetta esterna.\u003c\/li\u003e\n    \u003cli\u003eInserire la provetta esterna nel manicotto fisso e serrare la vite di fissaggio.\u003c\/li\u003e\n    \u003cli\u003eAllineare la vite di fissaggio con la scanalatura triangolare all'estremità superiore della provetta esterna prima della misurazione.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eNote di selezione\u003c\/h2\u003e\n  \u003cp\u003eSelezionare l'adattatore rotore 0# quando si misurano liquidi al di sotto di 15 mPa.s su un viscosimetro rotazionale NDJ o SNB compatibile. Si tratta di un set di accessori, non di un viscosimetro completo.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eFAQ\u003c\/h2\u003e\n  \u003ch3\u003eA cosa serve il set adattatore rotore 0#?\u003c\/h3\u003e\n  \u003cp\u003eViene utilizzato per la misurazione di liquidi a bassa viscosità su viscosimetri rotazionali NDJ e SNB compatibili.\u003c\/p\u003e\n  \u003ch3\u003eQuali modelli di viscosimetro sono compatibili?\u003c\/h3\u003e\n  \u003cp\u003eI modelli compatibili sono NDJ-5S, NDJ-8S, NDJ-9S, SNB-1 e SNB-2.\u003c\/p\u003e\n  \u003ch3\u003eQuale volume di campione utilizza?\u003c\/h3\u003e\n  \u003cp\u003eUtilizzare 20-25 mL di campione liquido nella provetta esterna.\u003c\/p\u003e\n  \u003ch3\u003ePer quale intervallo di viscosità è indicato questo accessorio?\u003c\/h3\u003e\n  \u003cp\u003eÈ per campioni a bassa viscosità da 0.01 mPa.s a 15 mPa.s.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43370947051609,"sku":"FMF-NDJ-5S-05369","price":99.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/Se8678d844e514e918b5ca37e09537835t.webp?v=1780390825"},{"product_id":"721-vis-spectrophotometer-lab-equipment-330-1020nm-4nm-bandwidth-110v-220v","title":"721 VIS Spectrophotometer 330-1020nm 4nm Bandwidth Lab Optical Meter","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe 721 VIS spectrophotometer is a laboratory optical meter designed for visible-light measurement over a 330-1020 nm wavelength range. This product notes 4 nm spectral bandwidth, T and A measurement modes, and 110V or 220V power requirements.\u003c\/p\u003e\n\u003ch2\u003eKey Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: 721 VIS spectrophotometer\u003c\/li\u003e\n\u003cli\u003eProduct type: laboratory spectrophotometer\u003c\/li\u003e\n\u003cli\u003eWavelength range: 330-1020 nm\u003c\/li\u003e\n\u003cli\u003eSpectral bandwidth: 4 nm\u003c\/li\u003e\n\u003cli\u003eMeasurement modes listed: T and A\u003c\/li\u003e\n\u003cli\u003eDisplay: 3 1\/2 LCD display\u003c\/li\u003e\n\u003cli\u003eSample chamber note: 50 mm optical distance \/ cuvette frame listed\u003c\/li\u003e\n\u003cli\u003e721-100 note: 100 mm cell rack for water analysis and sample content analysis\u003c\/li\u003e\n\u003cli\u003eSKU: FMF-TM-85497\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eConfirm the 721 model, wavelength range, bandwidth, cell rack needs, and 110V or 220V power requirements before ordering.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat is the 721 VIS spectrophotometer used for?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for laboratory visible-light measurement and sample content analysis applications.\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength range is listed?\u003c\/h3\u003e\n\u003cp\u003eThe listed wavelength range is 330-1020 nm.\u003c\/p\u003e\n\u003ch3\u003eWhat spectral bandwidth is listed?\u003c\/h3\u003e\n\u003cp\u003eThe listed spectral bandwidth is 4 nm.\u003c\/p\u003e\n\u003ch3\u003eWhat measurement modes are listed?\u003c\/h3\u003e\n\u003cp\u003eThis product notes T and A measurement modes.\u003c\/p\u003e\n\u003ch3\u003eWhat SKU identifies this product?\u003c\/h3\u003e\n\u003cp\u003eThe SKU is FMF-TM-85497.\u003c\/p\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43370961010777,"sku":"FMF-TM-85497","price":282.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/See682b64234e43d8903523944d9412427.webp?v=1780391038"},{"product_id":"sc-4-spin-coater-0-4-inch-substrate","title":"SC-4 Spin Coater 100-9999 rpm Programmable Vacuum Spin Coating Machine for 0-4 inch Substrate","description":"\u003csection\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe SC-4 is a compact laboratory spin coater for thin-film coating, wafer coating, and small substrate preparation up to 4 inches. It supports single-step and multi-step programs, allowing operators to set speed, time, and acceleration for controlled coating workflows.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100-9999 rpm adjustable spin speed range for laboratory coating work.\u003c\/li\u003e\n\u003cli\u003e100-9999 rpm\/s adjustable acceleration range.\u003c\/li\u003e\n\u003cli\u003eSingle-step and multi-step operation, with speed, time, and acceleration settings for each step.\u003c\/li\u003e\n\u003cli\u003eSingle-step time up to 3000 seconds.\u003c\/li\u003e\n\u003cli\u003e1 rpm speed resolution for fine process adjustment.\u003c\/li\u003e\n\u003cli\u003eBrushless DC motor for stable spin-coating operation.\u003c\/li\u003e\n\u003cli\u003eLCD display with button-control panel for direct setup and operation.\u003c\/li\u003e\n\u003cli\u003eChinese and English menu display, with language switching as needed.\u003c\/li\u003e\n\u003cli\u003eCompact body suitable for benchtop use and glove-box operation.\u003c\/li\u003e\n\u003cli\u003eAluminum alloy shell for a rigid laboratory equipment body.\u003c\/li\u003e\n\u003cli\u003eAC100-240V wide-voltage input for flexible lab power matching.\u003c\/li\u003e\n\u003cli\u003eStandard package includes a vacuum pump.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eUse the SC-4 for laboratory spin coating on substrates up to 4 inches, including wafer coating, glass slide coating, ITO conductive glass coating, and small sample preparation. Match the spin chuck and vacuum setup to the sample size and process requirement before use.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eSC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eLaboratory spin coater \/ spin coating machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessable substrate size\u003c\/th\u003e\n\u003ctd\u003eUp to 4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e100-9999 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration range\u003c\/th\u003e\n\u003ctd\u003e100-9999 rpm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum single-step time\u003c\/th\u003e\n\u003ctd\u003e3000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed resolution\u003c\/th\u003e\n\u003ctd\u003e1 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eBrushless DC motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShell material\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage\u003c\/th\u003e\n\u003ctd\u003eAC100-240V wide-voltage input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e208 mm (W) x 282 mm (D) x 218 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard package\u003c\/th\u003e\n\u003ctd\u003eSpin coater with vacuum pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eControls and Connections\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFront LCD display with button-control panel and switchable Chinese \/ English menu display.\u003c\/li\u003e\n\u003cli\u003eMode, pump, and start\/pause controls for routine operation.\u003c\/li\u003e\n\u003cli\u003eRear VAC port for connecting the vacuum line.\u003c\/li\u003e\n\u003cli\u003eTransparent hinged lid over the coating bowl.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThis model supports AC100-240V wide-voltage input and includes a vacuum pump as standard. Before ordering, confirm substrate size, spin chuck fit, plug type, and process-control requirements for your lab workflow.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat substrate size can the SC-4 process?\u003c\/h3\u003e\n\u003cp\u003eThe listed processable substrate size is up to 4 inches.\u003c\/p\u003e\n\u003ch3\u003eCan it run multi-step spin-coating programs?\u003c\/h3\u003e\n\u003cp\u003eYes. Single-step and multi-step operation are available, with speed, time, and acceleration settings for each step.\u003c\/p\u003e\n\u003ch3\u003eWhat is the speed range?\u003c\/h3\u003e\n\u003cp\u003eThe listed speed range is 100-9999 rpm, with 1 rpm resolution.\u003c\/p\u003e\n\u003ch3\u003eWhat is the shell material?\u003c\/h3\u003e\n\u003cp\u003eThe shell is aluminum alloy.\u003c\/p\u003e\n\u003ch3\u003eDoes the standard package include a vacuum pump?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard package includes a vacuum pump.\u003c\/p\u003e\n\u003ch3\u003eCan the menu language be switched?\u003c\/h3\u003e\n\u003cp\u003eYes. The instrument supports Chinese and English menu display, and the language can be switched as needed.\u003c\/p\u003e\u003c\/section\u003e","brand":"FMF","offers":[{"title":"Titolo predefinito","offer_id":43443504808025,"sku":"SC-4-AC100-240V","price":1429.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/sc-4-spin-coater-vacuum-pump-kit.jpg?v=1781783320"},{"product_id":"qhzs-001a-laboratory-syringe-pump-foot-pedal","title":"QHZS-001A Laboratory Syringe Pump with Foot Pedal, Infusion and Withdrawal, 0.01-150 mm\/min","description":"\u003csection\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe QHZS-001A is a laboratory syringe pump for controlled infusion and withdrawal. The A2 package adds a foot pedal for frequent start and stop operation while retaining manual, automatic, and communication control.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eA2 Package Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQHZS-001A syringe pump\u003c\/li\u003e\n\u003cli\u003eController\u003c\/li\u003e\n\u003cli\u003e12V power adapter\u003c\/li\u003e\n\u003cli\u003eFoot pedal switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSyringe is not included.\u003c\/strong\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInfusion and withdrawal operation.\u003c\/li\u003e\n\u003cli\u003eAdjustable travel speed from 0.01 to 150 mm\/min.\u003c\/li\u003e\n\u003cli\u003eManual, automatic, and communication control modes.\u003c\/li\u003e\n\u003cli\u003eFoot pedal input for hands-free start and stop control.\u003c\/li\u003e\n\u003cli\u003eUSB and UART serial communication support.\u003c\/li\u003e\n\u003cli\u003eController settings can be saved for repeated operation.\u003c\/li\u003e\n\u003cli\u003eThickened aluminum alloy profile frame with reinforced stainless steel guide rails.\u003c\/li\u003e\n\u003cli\u003eExtended flange bearings and thickened acrylic panels.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eController Button Instructions\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/qhzs-001a-controller-buttons-and-ports.png?v=1783820374\" alt=\"QHZS-001A controller buttons ports and foot switch connection diagram\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect a setting:\u003c\/strong\u003e Press the \u003cstrong\u003eMode\u003c\/strong\u003e button to display the arrow indicator. Move the arrow to the item you want to adjust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjust speed or time:\u003c\/strong\u003e When the arrow points to one of the first five settings, press \u003cstrong\u003eIncrease (+)\u003c\/strong\u003e or \u003cstrong\u003eDecrease (-)\u003c\/strong\u003e to adjust the speed integer value, speed decimal value, or time value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSave settings:\u003c\/strong\u003e When the arrow points to \u003cstrong\u003eSave\u003c\/strong\u003e, the sixth item, press the \u003cstrong\u003eSave\u003c\/strong\u003e button to store the parameters for future operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun the pump:\u003c\/strong\u003e When the arrow points to \u003cstrong\u003eRUN\u003c\/strong\u003e, the seventh item, press \u003cstrong\u003eAuto Forward\u003c\/strong\u003e or \u003cstrong\u003eAuto Reverse\u003c\/strong\u003e to operate automatically at the preset speed and time. Use \u003cstrong\u003eManual Forward\u003c\/strong\u003e or \u003cstrong\u003eManual Reverse\u003c\/strong\u003e for manual movement; release the manual button to stop.\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eQHZS-001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eInfusion and withdrawal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e0.01-150 mm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTravel\u003c\/th\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl modes\u003c\/th\u003e\n\u003ctd\u003eManual, automatic, communication control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported syringe diameter\u003c\/th\u003e\n\u003ctd\u003eUp to 50 mm; 200 mL syringes require a dedicated screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump dimensions\u003c\/th\u003e\n\u003ctd\u003e312 x 100 x 126 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower requirement\u003c\/th\u003e\n\u003ctd\u003e12V \/ 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain unit net weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eThickened aluminum alloy profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGuide rails\u003c\/th\u003e\n\u003ctd\u003eReinforced stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBearings\u003c\/th\u003e\n\u003ctd\u003eExtended flange bearings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePanels\u003c\/th\u003e\n\u003ctd\u003eThickened acrylic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eUSB and UART serial communication, 9600 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eQHZS-001A Communication Commands\u003c\/h2\u003e\n  \u003cp\u003eThe pump supports direct USB communication and UART serial communication at 9600 baud. With a suitable external UART converter, the host controller can communicate through RS232, RS485, or CAN. These converted interfaces require separate conversion hardware and are not built-in ports.\u003c\/p\u003e\n  \u003cp\u003eA computer or host controller can send the following commands to set operating values and control pump movement. In each command, \u003ccode\u003exx\u003c\/code\u003e is the value to be set; use the valid parameter range shown in the product specifications.\u003c\/p\u003e\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eCommand\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSet speed integer value\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ1HxxD\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSet speed decimal value\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ2HxxD\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSet hours\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ3HxxD\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSet minutes\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ4HxxD\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSet seconds\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ5HxxD\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSave parameters\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H1D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAutomatic forward\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H2D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAutomatic reverse\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H3D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReturn message after automatic operation\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eF1D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual forward\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H4D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual reverse\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H5D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStop\u003c\/td\u003e\n\u003ctd\u003e\u003ccode\u003eQ6H6D\u003c\/code\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n  \u003ch3\u003eUART Connection Note\u003c\/h3\u003e\n  \u003cp\u003eCommunication control requires a buyer-supplied connection tool; a CH340G module is generally recommended. Supplier diagrams show conflicting TX\/RX wiring conventions, so verify the labels and signal direction on the supplied controller and converter before connecting. Do not rely on wire color or an unverified pin-to-pin assumption.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/qhzs-001a-syringe-pump-dimensions.png?v=1783820227\" alt=\"QHZS-001A syringe pump dimension diagram\" loading=\"lazy\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\n  \u003ch2\u003eOperating Controls and Timer\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eThe foot pedal can replace the panel button for frequent start and stop operation.\u003c\/li\u003e\n    \u003cli\u003eSpeed settings support two decimal places within the model's stated 0.01-150 mm\/min travel-speed range.\u003c\/li\u003e\n    \u003cli\u003eRun duration can be set in hours, minutes, and seconds. The pump stops automatically when the configured time ends.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n  \u003ch2\u003eTypical Laboratory and Process Applications\u003c\/h2\u003e\n  \u003cp\u003eThe QHZS-001A can be used for controlled laboratory animal injection setups, nanomaterial experiments, wet spinning, electrospinning, cell-culture liquid handling, microfluidic control, industrial process trials, liquid sampling, and dispensing when the selected syringe, tubing, flow requirements, and operating setup are compatible.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003ch3\u003eCan this laboratory syringe pump perform both infusion and withdrawal?\u003c\/h3\u003e\n  \u003cp\u003eYes. The QHZS-001A supports forward infusion and reverse withdrawal through manual or automatic operation.\u003c\/p\u003e\n  \u003ch3\u003eCan the pump be started and stopped without using the panel buttons?\u003c\/h3\u003e\n  \u003cp\u003eYes. The included foot pedal provides hands-free syringe pump start and stop control for repeated laboratory or process work.\u003c\/p\u003e\n  \u003ch3\u003eWhat is the adjustable travel-speed range?\u003c\/h3\u003e\n  \u003cp\u003eThe syringe pump travel speed is adjustable from 0.01 to 150 mm\/min.\u003c\/p\u003e\n  \u003ch3\u003eWhat is the maximum mechanical travel?\u003c\/h3\u003e\n  \u003cp\u003eThe QHZS-001A has 140 mm travel. Select the syringe and operating setup so the required plunger movement remains within this range.\u003c\/p\u003e\n  \u003ch3\u003eWhat power supply is included?\u003c\/h3\u003e\n  \u003cp\u003eThe A2 package includes a 12V \/ 3A power adapter, controller, foot pedal, and pump. The syringe is not included.\u003c\/p\u003e\n\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eOrdering Note\u003c\/h2\u003e\n\u003cp\u003eThis listing is for the A2 Full Kit + Foot Pedal configuration only. Select a compatible syringe according to its outside diameter and required volume.\u003c\/p\u003e\u003c\/section\u003e","brand":"FMF","offers":[{"title":"A2 Full Kit + Foot Pedal","offer_id":43621264425049,"sku":"QHZS-001A-A2","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4354\/5177\/files\/QQ20260712-092950_6d5597e8-9c2d-428a-9fc4-b14fa37e76a1.png?v=1783825700"}],"url":"https:\/\/fmfpack.com\/it-it\/collections\/attrezzature-da-laboratorio.oembed","provider":"FMF Supply","version":"1.0","type":"link"}